All-dielectric construction is what lets fibre share a power alignment. There is no metallic member to induce into, so the span can be strung and maintained on an energised line. Annexure A tabulates 24F, 48F and 96F cable at 15 to 17 mm and 11.2 to 14 kN tensile strength.
Cable GR
TEC/GR/TX/OFC-022/01/SEP-11
01 — The problem
02 — Annexure A figures
- Cable diameter
- 15 – 17 mm
- Tensile strength
- 11.2 – 14 kN (6W)
- Cable weight
- 190 – 240 kg/km
- Anchoring load value
- 10.6 – 13.3 kN
- Bracket tensile strength
- 22.4 – 28 kN