Click the model to take it apart · drag to turn
SYN-T3-ADA · 3 parts
Anchoring (Dead End) Assembly
01 — Overview
End of runAngle > 20°Matched set
- Code
- SYN-T3-ADA
- Type
- Type-III — Wedge type
- Drawing
- TEC GR 13.1
Holds the cable firmly to a concrete, wood or steel pole and transmits the span tension into it — at the end of a run, or at a change of direction over twenty degrees. One wedge-type tension clamp and one pole or wall bracket, supplied together so the materials are known to be compatible.
02 — Specification
Data sheet
Figures quoted from the governing GR drawing tables and Annexure A. Values marked (P) pending production data.
- Application
- End of run, or direction change over 20°
- Pole types
- Concrete, wood or steel
- Bail length
- 400 mm minimum
- Load value
- 950 N – 15910 N by cable
- Bracket tensile strength
- 15 kN – 33.5 kN by cable
- Drawing
- TEC GR 13.1
03 — Bill of parts
- 01Dead End ClampPBT / polyamide with glass fibre
- 02Universal Pole BracketAluminium alloy GDC, IS 617
- 03Stainless Steel StrapASTM SS 202
04 — Why it's built this way
- Supplied in sets to ensure compatibility of the materials
- No losable part in the clamping arrangement
- Field trial invited before bulk procurement, per clause 14.2
Same type
All Type-III →SYN-T3-DECDRG 13.6
Hover · parts separatingDead-End Clamp
→Self-locking wedge clamp with a stainless bail and U-saddle.
Wedge self-lockingBail 400 mmReleases on overload
SYN-T3-UPBDRG 13.7
Hover · parts separatingUniversal Pole Bracket
→Single-piece cast aluminium bracket, strap or bolt fixed to any pole.
Cast, not extrudedOne bolt or two straps15 – 28 kN
SYN-T3-SCDRG 13.8
Hover · parts separatingSuspension Clamp
→Thermoplastic body and flange with an elastomer liner that lets the cable slip.
Deviation to 20°Slips 150–260 NStrap or M14 bolt