Skip to content
INFRA
Click the model to take it apart · drag to turn
SYN-T2-TPA · 7 parts

Tension Pole Assembly (Light Duty)

01 — Overview

Below 10 kN3W tensileStrap fixable
Code
SYN-T2-TPA
Type
Type-II — Helix type (Light duty)
Drawing
TEC GR 12.1

The Type-II termination: turn buckle, clevis or thimble, protective helix and terminating helix, onto either a pole clamp or a universal pole bracket with stainless strap. Sized for 11.2 to 14.7 mm cable at 3W tensile strength rather than 6W, which is what most urban and last-mile alignments actually carry.

02 — Specification

Data sheet

Figures quoted from the governing GR drawing tables and Annexure A. Values marked (P) pending production data.

Cable tensile strength
Below 10 kN (3W)
Cable diameter
11.2 – 14.7 mm
Maximum span
100 m
Turn angle
Exceeding 15 degrees
Pole fixing
Pole clamp or universal bracket
Drawing
TEC GR 12.1

03 — Bill of parts

  • 01
    Turn Buckle
    Forged steel or aluminium alloy
  • 02
    Clevis / Thimble
    Aluminium alloy GDC
  • 03
    Protective Helix (T)
    Aluminium alloy IS 6061
  • 04
    Terminating Helix
    Hot-dip galvanised steel
  • 05
    Pole Clamp or Universal Bracket
    Galvanised steel / aluminium alloy

04 — Why it's built this way

  • Universal pole bracket option removes per-pole-type inventory
  • Terminating helix rated at 135 kg/mm² ultimate tensile strength
  • Insulators may replace thimbles on power line alignments
Syntel Infra
TEC GR/TX/OAF-001/03
000