SYN-T2-DLC · 5 parts

Down Lead Clamp

01 — Overview

Vertical runsInsert 65–80 Shore ABuilding entry
Code
SYN-T2-DLC
Type
Type-II — Helix type (Light duty)
Drawing
TEC GR 12.4

Down lead clamps hold the cable in the vertical as it leaves the aerial run for a pole base or a building entry. The matching jumper clamp carries it in the horizontal. Both take a polychloroprene insert against the jacket.

02 — Specification

Data sheet

Figures quoted from the governing GR drawing tables and Annexure A. Values marked (P) pending production data.

Application
Vertical cable support
Insert material
Polychloroprene compounded
Insert hardness
65 – 80 Shore A
Insert compression
22 per cent maximum
Drawing
TEC GR 12.4

04 — Why it's built this way

  • Stops the wind working the cable against the pole
  • Insert tested to IS 3400 Part 10
Syntel Infra
TEC GR/TX/OAF-001/03
000